HOTLINE0086-13510878132

Color Camera Gray Scale Test Chart(with super black hole)

  • Product Description Two 9-graduated counter current gray scales are arranged on a gray background (D 0.75), the gray scales being graduated logarithmically (gamma = 0.45). The output of an optimally gamma-corrected camera yields two 9-gradu
  • Product details

  • Parameters


Product Description


Two 9-graduated counter current gray scales are arranged on a gray background (D ≈ 0.75), the gray scales being graduated logarithmically (gamma = 0.45). The output of an optimally gamma-corrected camera yields two 9-graduated counter current linear step signals. The contrast range of the gray scales is 50:1.


The values of the 9-graduated gray scale are as follows


Step Density Remission in % Output voltage in %
1 0.22 60 100
2 0.32 48 88.75
3 0.44 36 77.5
4 0.57 26 66.25
5 0.73 19 55
6 0.91 12 43.75
7 1.13 07 32.5
8 1.43 04 21.25
9 1.85 01.4 10
The density values are based on a density of BaO4S= 0.

The test chart incorporates a super black cavity for the accurate adjustment of camera flare corrections and setting of black level. On both sides of the super black hole 4.5 and 5.5MHz bars with a contrast ratio of 7:1 are located. Above and below the gray scales there are additional markings for the 16:9 format.
Color Camera Gray Scale Test Chart(with super black hole)